Catalogue · Safety cabinets

Laboratory safety storage cabinets

Type 90 cabinets for flammables (EN 14470-1) and gas cylinders (EN 14470-2), cabinets for acids and bases, and general storage integrated into the laboratory.

Request a quote2026 catalogue (PDF, Spanish)

Laboratory fitted out by Romero at Imperial College London

Safe storage

Every substance in the right cabinet

Storing flammable or corrosive reagents in the right cabinet reduces the risk of fire and exposure to vapours. We integrate safety cabinets into the laboratory design together with the rest of the furniture and extraction, including models that fit under the fume cupboard.

Type 90 safety cabinets

90 minutes of fire resistance

For flammable liquids

  • 90 minutes of fire resistance, tested to EN 14470-1.
  • GS approval and CE marking. Compliant with EN 14727.
  • Doors and ducts that close automatically in a fire.
  • Widths of 600, 900 and 1,200 mm (1,968 mm high) and under-fume-cupboard models.
  • Integrated duct for forced ventilation.

For gas cylinders

  • For 2 to 4 cylinders of 50 litres, tested to EN 14470-2.
  • Tall interior (1,858 mm) and 24 top openings for pipework.
  • Loading ramp, adjustable cylinder holders and retaining straps.
  • Widths of 600, 900 and 1,200 mm.
  • Bottom-to-top ventilation.

Corrosives cabinets

Acids and bases

  • In technical board or epoxy-coated steel, 600 or 1,200 mm wide.
  • Polypropylene or stainless-steel sumps.
  • 10 mm PP full-extension trays.
  • Optional anti-corrosion forced ventilation.

General storage

Glass-fronted cabinets and shelving

  • Tall cabinets 2,050 mm high, 900 or 1,200 mm wide.
  • Wall cabinets of 900, 1,200 and 1,500 mm, with wooden or sliding glass doors.
  • Adjustable shelves and optional locks.
  • Metal version with A1 fire rating.

FAQ

Frequently asked questions

Which standard applies to flammable storage cabinets?

EN 14470-1. Our Type 90 cabinets are tested to this standard and offer 90 minutes of fire resistance. Gas cylinder cabinets are covered by EN 14470-2.

What does “Type 90” mean?

That the cabinet withstands 90 minutes in the standard fire test, giving time to evacuate and for fire services to act before the contents are affected.

Can they go under the fume cupboard?

Yes. We make under-fume-cupboard models for flammables and ventilated cabinets for corrosives that integrate with the fume cupboard.

Do they need ventilation?

Flammables cabinets have an integrated duct for forced ventilation and gas cylinder cabinets ventilate from bottom to top. For corrosives cabinets, anti-corrosion forced ventilation is optional.